Production Improvement Efforts by Doing Condensate Trap from Gas Flare on EPF (Early Production Facilities)
DOI: 10.54647/energy48151 77 Downloads 221130 Views
Author(s)
Abstract
Field "X" one of the oil and gas fields was have 3 operating wells. The daily production of oil and gas up to April 27, 2019, was 215 BOPD and gas was 0.15 MMSCFD, where previously the produced gas was discharged by flare and oil was flowed directly to the collecting station. The problem with this research is that the original gas in the flare still contains hydrocarbon compounds and water which is marked on a black-coloured flaring fire. Therefore, the researchers innovated that the gas production of the "X" Field that had previously only been removed (flaring) would be converted to be produced into condensate and could reduce CO2. The methodology in this study begins by determining the composition of gas by using the Gas Chromatograph tool. Then a simulation is performed to obtain condensate recovery with the help of the Process Simulation software, by which trial and error methods are applied. This study uses two types of heat exchanger devices, namely fin-fan and chiller. Device with the most produced condensate is chosen for further study and field application. The results are based on simulation with consideration to temperature and pipe size sensitivity. The gas production of 0.15 MMSCFD from the "X" Field can produce condensate of 4.10 BBL of condensate by using a chiller. The chiller is the most representative tool for conducting this condensation process after being validated using software simulation process. The application of chiller will eliminate the need of gas scrubber, hence creating more affordable facility and the produced condensate can be sold. The absence of gas scrubber can save cost up to 1,370.53 $/month and the produced condensate will create additional revenue as much as 205 $/day, with the assumption of condensate price constant at $50.
Keywords
chiller, condensate trap, early production facilities, fin-fan.
Cite this paper
Edgie Yuda Kaesti, Heriyanto, Theomas Abdi Jaya, Michael Janzen Arinatama, Adha Bayu Wijaya,
Production Improvement Efforts by Doing Condensate Trap from Gas Flare on EPF (Early Production Facilities)
, SCIREA Journal of Energy.
Volume 6, Issue 6, December 2021 | PP. 113-129.
10.54647/energy48151
References
[ 1 ] | Amrullah, et. al., “Analisa Kinerja Mesin Refrigerasi Rumah Tangga dengan Variasi Refrigeran,” 2017. |
[ 2 ] | Aregbe, Azeez G., “Natural Gas Flaring – Alternative Solutions”, Journal of Engineering Technology, no. 5, pp. 139 – 15, 2017. DOI: https://doi.org/10.4236/wjet.2017.51012. [Accessed August 2020]. |
[ 3 ] | AspenTech, “Official Website of AspenTech Company,” Aspen Technology, 1994-2005. [Online]. Available: www.aspentech.com. |
[ 4 ] | Aziz, Azridjal, et. al., “Penggunaan Thermal Energy Storage sebagai Penyejuk Udara Ruangan dan Pemanas Air pada Residential Air Conditioning Hibrida,” Banjarmasin: Proceeding Seminar Nasional Tahunan Teknik Mesin XIV, 2015. |
[ 5 ] | Aziz, Azridjal and Herisiswanto, “Pengembangan Energy Efficient Residential Air Conditioning Systems dengan Encapsulated Ice Thermal Energy Storage Berbasis Mesin Refrigerasi Kompresi Uap Menggunakan Refrigeran Hidrokarbon Substitusi R-22 yang Ramah Lingkungan,” Pekanbaru: Lembaga Penelitian Universitas Riau, 2009. |
[ 6 ] | Changjun Li, Yang Peng, Jingya Dong, “Prediction of the Dew Point Pressure for Gas Condensate Using a Modified Peng-Robinson Equation of State and a Four-coefficient Molar Distribution Function,” Journal of Natural Gas Science and Engineering, Vol. 27, pp. 967-978, 2015. DOI: https://doi.org/10.1016/j.jngse.2015.09.034. |
[ 7 ] | Director General of Oil and Gas, “Pemerintah Targetkan Zero Flare Pada Tahun 2025,” Jakarta: Ministry of Energy and Mineral Resources, 2010. [Online]. Available: https://www.esdm.go.id/id/media-center/arsip-berita/pemerintah-targetkan-zero-flare-pada-tahun-2025. |
[ 8 ] | Fares, A. D, “Process Simulation Using Aspen HYSYS V.8.8,” 2016. |
[ 9 ] | Hudson Product Corporation, “The Basic of Air-Cooled Heat Exchangers,” 2007. |
[ 10 ] | Kolmetz, Karl, “Kolmetz Handbook of Process Equipment Design: Fin-fan Air Cooler Selection and Sizing,” Malaysia: KLM Technology Group, 2015. |
[ 11 ] | Odumugbo, Charles Asekhame, “Natural Gas Utilisation in Nigeria: Challenges and Opportunities,” Chemical Engineering, no. 2, pp. 310 – 316, 2010. DOI: |
[ 12 ] | Ojijiagwo, Emeka, et. al., “Economics of Gas to Wire Technology Applied in Gas Flare Management,” Engineering Science and Technology, an International Journal, no. 19, pp. 2109 – 2118, 2016. DOI: http://dx.doi.org/10.1016/j.jestch.2016.09.012. |
[ 13 ] | Rotty, Ralph M., “First Estimates of Global Flaring of Natural Gas,” Atmospheric Environment, vol. 8, pp. 681 – 686, 1973. DOI: https://doi.org/10.1016/0004-6981(74)90159-0. |
[ 14 ] | Schlumberger, “Oilfield Dictionary, USA: Schlumberger Limited, 2019. [Online]. Available: https://www.glossary.oilfield.slb.com/Terms/c/condensate.aspx. [Accessed May 2019]. |
[ 15 ] | Smith, P. et, al., “Tutorials & Applications HYSYS 3.1,” Cambridge: Aspen Technology, 2002. |
[ 16 ] | Yusuf, Jefry, Husni Husin, dan Marwan, “Simulasi Pengaruh Kandungan CO2 dalam Ga8s Umpan terhadap Re-forming dan Shift Converter Sistem Pabrik Amoniak,” Jurnal Rekayasa Kimia dan Lingkungan, vol. 10, no. 4, pp. 178 – 187, 2015. |